Calculator · Sheet metal, parts, threads
FLAT LENGTHWITH K-FACTOR.
In bending the outside is stretched and the inside compressed. In between lies the neutral axis, which keeps its length. The flat length is the sum of the straight sections and the arc lengths along the neutral axis. Where the axis lies is described by a factor that you enter. The calculation is an approximation and only as good as that factor.
The calculator works with formulas only. You enter values from standards, handbooks and data sheets yourself. Check results before manufacturing.
Formula
is the number of bends.
Arc length of the neutral axis for the bend angle .
K-factor
Position of the neutral axis from the inside: K-factor as used in CAD programs such as Autodesk Fusion.
Correction factor
The same position with the correction factor as written in DIN 6935. Both describe the same thing: .
Per adjacent bend, for outside dimensions. For inside dimensions use instead of . At 90°, .
Quantities and units
| Flat length (blank) | mm | |
| , , | Flange dimensions to the virtual intersection of the outer or inner faces | mm |
| Sheet thickness | mm | |
| Inside bend radius | mm | |
| Bend angle: 90° for a right angle | ° | |
| , | Factor for the position of the neutral axis | – |
Worked example
Buggy seat: angle 25 × 25 mm outside, 2 mm sheet
Given:
For comparison, the rear body: U-profile with inside dimensions 50, 70 and 50 mm,
, . Straight sections , two arcs of each, . That is the value on the drawing.
Common mistakes
- Inside and outside dimension confused: the result is wrong by per bend, two sheet thicknesses at 90°.
- K-factor and correction factor confused: a k value entered as K-factor puts the neutral axis twice as far out.
- Bend angle and opening angle confused: a sheet bent by 60° has an opening angle of 120°.
- Springback forgotten: the flat length is right, the angle is not. Set the angle with a test bend.
- Factor taken without checking: the right value depends on material, ratio and bending process. A measured test bend is more accurate than any table value.
In the training project
The buggy involves bending: the rear body is a U-profile of 1 mm steel sheet whose flat length is on the drawing; apprentices calculate the seat of 2 mm sheet themselves.
The truck’s loading floor is a U-profile of 1 mm sheet with an inside radius of R2.5. Its mass lets you work back to the blank width.
View project: Truck – batch production with a tolerance system
Frequently asked questions
Which K-factor should I use?
The value of your CAD sheet metal rule if drawing and blank are to match, or a value from a test bend. The buggy part dossiers use K = 0.44. There is no universally valid value.
What does DIN 6935 cover?
DIN 6935 deals with cold bending of flat steel products, including calculating the flat length with a correction factor. The standard’s values and tables are not reproduced here; for those you need the standard itself or your reference handbook.