Skip to content
Stern Didactic GmbH

Calculator · Sheet metal, parts, threads

FLAT LENGTHWITH K-FACTOR.

In bending the outside is stretched and the inside compressed. In between lies the neutral axis, which keeps its length. The flat length is the sum of the straight sections and the arc lengths along the neutral axis. Where the axis lies is described by a factor that you enter. The calculation is an approximation and only as good as that factor.

All calculators

Formula

  • is the number of bends.

  • Arc length of the neutral axis for the bend angle .

  • K-factor

    Position of the neutral axis from the inside: K-factor as used in CAD programs such as Autodesk Fusion.

  • Correction factor

    The same position with the correction factor as written in DIN 6935. Both describe the same thing: .

  • Per adjacent bend, for outside dimensions. For inside dimensions use instead of . At 90°, .

Quantities and units

Flat length (blank)mm
, , Flange dimensions to the virtual intersection of the outer or inner facesmm
Sheet thicknessmm
Inside bend radiusmm
Bend angle: 90° for a right angle°
, Factor for the position of the neutral axis–

Worked example

Buggy seat: angle 25 × 25 mm outside, 2 mm sheet

Given: (outside), , , ,

  1. For comparison, the rear body: U-profile with inside dimensions 50, 70 and 50 mm, , . Straight sections , two arcs of each, . That is the value on the drawing.

Common mistakes

In the training project

Frequently asked questions

Which K-factor should I use?

The value of your CAD sheet metal rule if drawing and blank are to match, or a value from a test bend. The buggy part dossiers use K = 0.44. There is no universally valid value.

What does DIN 6935 cover?

DIN 6935 deals with cold bending of flat steel products, including calculating the flat length with a correction factor. The standard’s values and tables are not reproduced here; for those you need the standard itself or your reference handbook.

More calculators

Sources